E: Motor Parameters - YASKAWA L1000A Technical Manual

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

No.(Addr.)
Name
d1-26
(2C8H)
Leveling Speed
d1-27
Motor 2 Speed Reference
(2C9H)
d1-28
Leveling Speed Detection Level
(2CAH)
d1-29
Inspection Speed Detection Level
(2CBH)
<6> Setting ranges and defaults vary by the setting units determined by parameter o1-03.
Refer to
Defaults and Setting Ranges by Display Unit Selection (o1-03) on page 382
d6: Field Forcing
No.(Addr.)
Name
d6-03
Field Forcing Selection
(2A2H)
d6-06
Field Forcing Limit
(2A5H)

◆ E: Motor Parameters

E1: V/f Pattern
No.(Addr.)
Name
E1-01
Input Voltage Setting
(300H)
E1-03
V/f Pattern Selection
(302H)
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Description
All Modes
Sets leveling speed reference when d1-18 = 1 or 2.
V/f
OLV
Sets the speed reference for motor 2.
Note: 1. If set to 0.00, the drive will control motor 1 instead.
2. When using motor 2, be sure that the accel/decel times are set in parameters C1-12
and C1-13.
All Modes
Used when d1-18 = 0 or 3. If the speed reference selected is lower than d1-28, then the drive
uses the leveling speed as the speed reference.
All Modes
Used when d1-18 = 0 or 3. If the speed reference selected is higher than d1-28 but lower or
equal to d1-29, then the drive uses inspection speed as the speed reference.
Description
V/f
OLV
0: Disabled
1: Enabled
V/f
OLV
Sets the upper limit of the excitation current command during magnetic field forcing. A setting
of 100% is equal to motor no-load current. Disabled only during DC Injection Braking.
Description
All Modes
This parameter must be set to the power supply voltage.
WARNING! Electrical Shock Hazard. Drive input voltage (not motor voltage) must be set in
E1-01 for the protective features of the drive to function properly. Failure to do so may result in
equipment damage and/or death or personal injury.
V/f
OLV
F: Custom V/f, E1-04 through E1-13 settings define the V/f pattern
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
common_
Default:
TMonly
8.00%
Min: 0.00%
167
<6>
Max: 100.00%
<6>
common_
TMonly
Default: 0.00 Hz
Min: 0.00 Hz
167
Max: 120.00 Hz
common_
Default: 0.00%
TMonly
Min: 0.00%
167
Max: 100.00%
common_
Default: 0.00%
TMonly
Min: d1-28
167
Max: 100.00%
Setting
Page
common_
Default: 0
TMonly
Min: 0
168
Max: 1
common_
Default: 400%
TMonly
Min: 100%
168
Max: 400%
Setting
Page
common_
TMonly
Default: 230 V
<9>
Min: 155 V
169
Max: 255 V
<9>
common_
Default: F
TMonly
Min: –
169
Max: F
B
345