5.3 C: Tuning
A Fast Stop can be selected as the action the drive should take when certain faults occur, such as L8-03 (Overheat Pre-
Alarm Operation Selection).
No.
C1-09
<1> The setting range and default value depend on the display units set in parameter o1-03. If o1-03 is set between 0 and 4, the time required to go
from 0% speed to 100% maximum speed is expressed in seconds. If o1-03 is set to 5 or 6, then setting units will appear in m/s
drive is in V/f control mode, the Fast stop ramp can be set in seconds only.
NOTICE: Rapid deceleration can trigger an overvoltage fault. The drive output shuts off when faulted and the motor coasts. Set an
appropriate Fast Stop time to C1-09 to avoid this uncontrolled motor state and to ensure that the motor stops quickly and safely.
C1-10: Accel/Decel Setting Resolution
Determines the units for the acceleration and deceleration ramps set to C1-01 through C1-09 using parameter C1-10.
No.
C1-10
Setting 0: Two decimal places
Setting 1: One decimal place
C1-12/C1-13: Motor 2 Acceleration Time/Motor 2 Deceleration Time
Sets the accel/decel time when motor 2 has been selected using one of the multi-function input terminals (H1-
No.
C1-12
C1-13
C1-15: Inspection Deceleration Ramp
Sets the deceleration ramp during Inspection Run. Refer to
No.
C1-15
<1> The setting range and default value depend on the display units set in parameter o1-03. If o1-03 is set between 0 and 4, the time required to go
from 0% speed to 100% maximum speed is expressed in seconds. If o1-03 is set to 5 or 6, then setting units will appear in m/s
drive is in V/f control mode, the inspection deceleration ramp can be set in seconds only.

◆ C2: Jerk Settings

Jerk settings set the transition between acceleration rates. Adjust them to smooth out jerks or shocks that occur when the
speed is changed.
C2-01 to C2-05: Jerk Settings
C2-01 through C2-05 set separate jerks for each section of the acceleration or deceleration.
No.
C2-01
C2-02
C2-03
C2-04
C2-05
<1> The setting range and default value depend on the display units set in parameter o1-03. If o1-03 is set between 0 and 4, the time required to go
from 0% speed to 100% maximum speed is expressed in seconds. If o1-03 is set to 5 or 6, then setting units will appear in m/s
156
Parameter Name
Fast Stop Ramp
Parameter Name
Accel/Decel Setting Resolution
Parameter Name
Motor 2 Acceleration Time
Motor 2 Deceleration Time
Inspection Operation on page 118
Parameter Name
Inspection Deceleration Ramp
Parameter Name
Jerk at Accel Start
Jerk at Accel End
Jerk at Decel Start
Jerk at Decel End
Jerk below Leveling Speed
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Setting Range
0.0 to 600.0 s
<1>
2
or ft/s
Setting Range
0 or 1
Setting Range
0.00 to 600.00 s
0.00 to 600.00 s
for details.
Setting Range
0.00 to 2.00 s
<1>
2
Setting Range
0.00 to 10.00 s
<1>
2
or ft/s
Default
1.50 s
<1>
2
. If the
Default
0
=16).
Default
1.00
1.00
Default
0.00 s
<1>
2
or ft/s
. If the
Default
0.50 s
<1>
2
.