F5: Digital Output Card Settings - YASKAWA L1000A Technical Manual

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

No.
F4-02
F4-04
F4-05
F4-06
Using Gain and Bias to Adjust Output Signal Level
When viewing the values set to F4-02 or F4-05 on the digital operator, a voltage equal to 100% of the parameter being
viewed (including current gain and bias settings) will be output from terminal V1 or V2. When viewing the value set to
F4-05 or F4-06, terminal V1 or V2 will output a voltage equal to 0% of the parameter being viewed (including current
gain and bias settings).
Example 1: F4-02 = 0%, F4-02 = 80%. When the parameter setting display for F4-02 is accessed using the digital
operator, terminal V1 will output a voltage of 8 V, even when the drive is stopped.
Example 2: F4-03 = 5%. When the parameter setting display for F4-03 is accessed using the digital operator, terminal V1
will output a voltage of 0.5 V, even when the drive is stopped.
F4-07, F4-08: Terminal V1, V2 Signal Level Selection
Sets the output signal level for terminals V1 and V2.
No.
F4-07
F4-08
Setting 0: 0 to 10 V
Setting 1: -10 to 10 V

◆ F5: Digital Output Card Settings

These parameters set up the drive for operation with the digital output option card DO-A3. Refer to the instruction manual
packaged with the option card for specific details on installation, wiring, input signal level selection, and parameter setup.
F5-01 through F5-08: Digital Output Option Card Terminal Function Selection
When F5-09 = 2, the parameters listed in the table below are used to assign functions to the output terminals on the option
card.
No.
F5-01
Terminal P1-PC Output Selection
F5-02
Terminal P2-PC Output Selection
F5-03
Terminal P3-PC Output Selection
F5-04
Terminal P4-PC Output Selection
F5-05
Terminal P5-PC Output Selection
F5-06
Terminal P6-PC Output Selection
F5-07
Terminal M1-M2 Output Selection
F5-08
Terminal M3-M4 Output Selection
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Parameter Name
Terminal V1 Gain
Terminal V2 Gain
Terminal V1 Bias
Terminal V2 Bias
Parameter Name
Terminal V1 Signal Level Selection
Terminal V2 Signal Level Selection
Name
Setting Range
0 to 161
0 to 161
0 to 161
0 to 161
0 to 161
0 to 161
0 to 161
0 to 161
5.6 F: Option Settings
Setting Range
-999.9 to 999.9%
-999.9 to 999.9%
-999.9 to 999.9%
-999.9 to 999.9%
Setting Range
0, 1
0, 1
Default
0: During run
1: Zero speed
2: Speed agree
4: Speed detection 1
6: Drive ready
37: During frequency output
F: Not used
F: Not used
Default
100.0%
50.0%
0.0%
0.0%
Default
1
1
5
181