S4: Rescue Operation - YASKAWA L1000A Technical Manual

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

S3-40: Anti-Rollback Movement Detection
Sets the amount of speed feedback signal pulses to detect a movement of the rotor.
No.
S3-40
S3-41: Position Lock Gain at Start 2 Reduction
Sets a reduction factor for the Position Lock Gain at Start 2 (Anti Rollback Gain) set in parameter S3-02.
If the motor rotation (i.e., car movement) is below the movement detection level set to S3-40, the drive will reduce the
Anti-Rollback gain according to the gain reduction level set in S3-41.
No.
S3-41

◆ S4: Rescue Operation

Rescue Operation switches to a backup battery or some other UPS during a power outage. Refer to
page 123
for details.
S4-01: Light Load Direction Search Selection
Enables and disables the Light Load Direction Search.
No.
S4-01
0: Disabled
1: Enabled
2: Enabled for motor 1 only
S4-02: Light Load Direction Search Method
Determines the method used to perform Light Load Direction Search.
No.
S4-02
0: Output current
1: Detect direction of regeneration
S4-03: Light Load Direction Search Time
Sets the time to perform Light Load Direction Search.
No.
S4-03
S4-04: Light Load Direction Search Speed Reference
Sets the speed reference to use during Light Load Direction Search.
No.
S4-04
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Parameter Name
Anti-Rollback Movement Detection
Parameter Name
Position Lock Gain at Start 2 Reduction
Parameter Name
Light Load Direction Search Selection
Parameter Name
Light Load Direction Search Method
Parameter Name
Light Load Direction Search Time
Parameter Name
Light Load Direction Search Speed Reference
5.11 S: Elevator Parameters
Setting Range
Default
0 to 100 pulses
1 pulse
Setting Range
Default
0.00 to 1.00
Rescue Operation on
Setting Range
Default
0 to 2
Setting Range
Default
0 or 1
Setting Range
Default
0.0 to 5.0 s
Setting Range
Default
0.00 to 20.00%
Determined by A-02
0.50
0
1
5
1.0 s
237