Voice terminal lights are dim, especially when the voice terminal T/P switch is in
Symptom:
the T position.
Possible Cause
The control unit is not supplying
enough power. The system may
need an Auxiliary Power Unit.
100
80
60
Total number of
5-, 10-, & 34-button
voice terminals,
40
and Hands-Free Units
20
Control unit power
supply is sufficient
TROUBLE ON SEVERAL TELEPHONES
Recommended Action
To see if an Auxiliary Power Unit (or another
Auxiliary Power Unit) is necessary, unplug three
voice terminals from the same Voice Terminal
Module at the control unit. (Auxiliary Power Units
support voice terminals in groups.) If the lights at
the remaining voice terminals are no longer dim, the
system needs an Auxiliary Power Unit.
The graph below also indicates when an Auxiliary
Power Unit is necessary.
20
10
Total number of 34-button
deluxe voice terminals
One Auxiliary Power Unit
is necessary
Lights
50
40
30
Two Auxiliary Power Units
are necessary
B4-3