(Z1A) AUTOMATIC MULTIPURPOSE ADAPTER (2301-ATR)
INSTALLATION
Connect the modular adjunct cord (D8AC) between the OTHER jack on the bottom of the
voice terminal and the OTHER jack on the back of the adapter.
Application I: Answering Machines
To use answering machines you must first program the Auto Answer Outside fea-
NOTE:
ture in your voice terminal. (Refer to the Administration Manual for 1030 and
3070 control units.)
Answering Machines Connected to Voice Jack
Connect the cord (D4CH) from the answering machine to the VOICE jack on the adapter
1.
(answering machine turns on).
Press the Voice button on the adapter (ringing directed to the answering machine).
2.
Answering Machine Connected to Data Plug
Connect one end of the 25-pin cable (RS232) to the plug on the 212A modem, which nor-
3.
mally connects to the data phone. Connect the other end of this cable to the DATA plug
on the adapter.
Press the Data button on the adapter (Voice button should be in up position) to direct
4.
ringing to the answering machine.
Application II:
Standard Modular Modems
Connect the modular cord (D4CH) from the modem to the VOICE jack on the back of the
1.
adapter (Figure 2).
NOTE:
Make sure both the Voice and Data buttons are in the "up" position by depress-
ing the Data button and releasing it.
VOICE TERMINAL
D8AC
ADAPTER
COMPUTER TERMINAL
D4CH
" O T H E R "
JACK
MODEM
VOICE
(MODULAR)
JACK
Figure 2