5.
Insert the top screw to help keep all the holes aligned and drill the re-
maining holes.
6.
Align the slat on the wall so that the bottom screw hole is located 3½
feet from the floor.
7.
Using one of the screws as a center punch, place it in each of the holes
and tap it lightly with a hammer to mark the wall.
8.
Measure 15 inches center-to-center for the second standard.
9.
Repeat steps 4 through 8 for the second standard.
If you are mounting the standards on a plywood wall, use a 1/8" drill
10a.
bit to drill all eight holes. Align the slats and standards and secure to
the wall with the screws.
b.
If you are mounting the standards on a sheetrock wall, use a ½" drill
bit to drill all eight holes. Insert a toggle bolt through each of the holes
of one standard and slat and thread a wing nut onto the ends of the
bolts. Fold the wings of the nuts together and push the bolts through
the holes in the wall until the wings spring open. Pull the slat and the
standard back toward you to hold the nuts against the inside wall; tighten
the bolts. Repeat this procedure with the other slat and standard (Figure
3).
Standard
Toggle
Bolt
Slat
Figure 3.
Mounting the Standards on a Sheetrock Wall
Sheetrock
Wall
Wing Nut

Advertisement