Merlin 3070 Service And Maintenance Manual page 198

Hide thumbs Also See for 3070:
Table of Contents

Advertisement

DETAIL
MESSAGE
none
REMT
*S[number] DLNC
*S[number] IMPR
*S[number] LCC
*S[number] NETW
MEANING
Remote Interface Active
This message indicates that diagnostics are ready for a
keyboard command.
DLNC Circuit Failure
1.
Repeat the sweep (press Next, then Detail) to verify
the existence of the problem.
2.
If the problem persists, check for bent or broken pins
in the slot listed. If the pins are undamaged, replace
the module.
Improper Module Type
The module in slot [number] is recognized by diagnostics
as an improper type for that slot. Slot 7 may only contain
Line Modules, and slot 9 may contain a Voice Terminal or
Basic Telephone Module.
Line Circuit Controller Failure
1.
Repeat the sweep (press Next, then Detail) to verify
the existence of the problem.
2.
If the problem persists, check for bent or broken pins
in the slot listed. If the pins are undamaged, replace
the module.
Voice Network Failure
1.
Repeat the sweep (press Next, then Detail) to verify
the existence of the problem.
2.
If the problem persists, disconnect all cords from the
module in the slot listed. Repeat the sweep.
3.
If the problem persists, check for bent or broken pins
in the backplane of the slot.
4.
Replace the module in the slot.
23