Merlin 3070 Service And Maintenance Manual page 196

Hide thumbs Also See for 3070:
Table of Contents

Advertisement

MESSAGE
DETAIL
none
ERTB
*INT
RST
CPU
DGM
S[number]
EXP
MAN
none
*MEM
CRPT
MEANING
Error Table Dump
The diagnostics error table is currently being dumped to
the data terminal. No user action is necessary.
Unexpected Exception
An unexpected interrupt has occurred during testing.
Perform the action appropriate to the detail message here
only if the interrupt persists when diagnostics are repeated
several times. Repeat the sweep of tests after performing
the recommended action. Check for bent or broken pins
at the backplane before replacing modules.
Unexpected reset. Check for loose power connections.
Check that all modules are firmly seated.
Unexpected Processor Module interrupt. Replace the
Processor Module.
Unexpected Diagnostics Module interrupt. Replace the
Diagnostics Module.
Unexpected slot interrupt. Replace the module in the
indicated slot.
Unexpected expansion interrupt. Check the expansion
system in slot marked Module A).
Autolog Mode Disabled
The automatic error logging mode has been disabled at
the data terminal user interface. No action necessary.
Translation Memory Corrupted
Translation memory has been corrupted. Users may have
to reprogram their voice terminals.
21