Cabling A Superloop Network Card - Multiple Columns - Avaya 1000M Installation And Commissioning Manual

Communication server
Hide thumbs Also See for 1000M:
Table of Contents

Advertisement

Page 384 of 436
Cabling a Superloop Network Card – multiple columns
NN43021-310
Standard 06.01
Cabling network modules and loops
If the system is configured as a single column"Basic cabling for single-row
network connections" on
CAUTION — Service Interruption
System Failure
Due to the possibility of EMI/RFI noise, do not route
cables from front to rear next to the power supply
unit.
Procedure 72
Basic cabling for multiple-row network connections
1
Refer to the work order and the cabling layout shipped with the system to
determine:
Each loop number assigned
The module and slot assignments of the NT8D04 Superloop Network
Card associated with each loop
The location of NT8D37 IPE Modules that contain NT8D01 Controller
Cards associated with each loop
2
Set the Enb/Dis switch on the faceplate of each network card to Dis.
3
Install NT8D1107 Superloop Adapter Plates on universal I/O panels
(P0715058), if required. The superloop adapter plate reduces a QPC414
network loop cutout to the size for a superloop connection.
The recommended order for installing superloop adapter plates is over
I/O panel locations J2, J6, J10, J22, J26, J31.
Position the adapter plate over the QPC414 cutout, and install the
screw and washer at the bottom of the plate.
Position the cable connector on the adapter plate, and install one
screw and washer at the top and one screw and washer at the bottom
of the connector.
Figure 138 on
page 386
adapter plate.
March 2013
page
380.
shows mounting details for the superloop