Table 46
NT5K19 Flexible E&M 2-Wire Type 1 connections for NT8D37 I/O panel
connectors A, E, K, R
Pair
T0
R0
E
M
T1
R1
E
M
T2
R2
E
M
T3
R3
E
M
Pair
Pins
color
27
W-O
2
O-W
28
W-G
3
G-W
31
R-BL
6
BL-R
32
R-O
7
O-R
35
R-S
10
S-R
36
BK-BL
11
BL-BK
39
BK-BR
14
BR-BK
40
BK-S
15
S-BK
Cabling lines and trunks
I/O panel connectors
A
E
Slot 0
Slot 4
Slot 0
Slot 4
Slot 0
Slot 4
Slot 0
Slot 4
Large System Installation and Commissioning
Page 269 of 436
K
R
Slot 8
Slot 12
Slot 8
Slot 12
Slot 8
Slot 12
Slot 8
Slot 12
Unit
number
Unit 0
Unit 1
Unit 2
Unit 3