Avaya 1000M Installation And Commissioning Manual page 381

Communication server
Hide thumbs Also See for 1000M:
Table of Contents

Advertisement

3
Cable network loops from the faceplate connector on the superloop
network card to the backplane for associated controller cards (see
Table 63 on
page
Label both ends of an NT8D91 cable with the loop number, then
connect one end of the cable to the superloop network card faceplate
connector:
— J1 for Shelf 1
— J2 for Shelf 0
On the backplane for the controller card, connect the cable to the
SL0, SL1, SL2, or SL3 connector assigned to the loop.
Note: The key (polarizing tab) on the side of the cable connector must be
inserted into the keyway on the left side, facing the backplane, of the
backplane connector. Blue and white wires should show through the top
of the cable connector and, if there is a directional label, the arrow on the
cable connector should be located at the top right.
Figure 137 on
page 383
connectors, the backplane connectors for the controller card, and the
cables required.
4
Seat and secure all connectors.
5
Set the Enb/Dis switch on each network card to Enb.
6
During system software configuration, use the Software Input/Output:
Administration (NN43001-611) to enter loop assignments.
Cabling network modules and loops
382).
shows the superloop network card faceplate
End of Procedure
Large System Installation and Commissioning
Page 381 of 436