Adding a module to a column
9
Connect the orange power connector to the module power harness.
Restore power to the module:
With AC power, set the main circuit breaker to ON (up) in the rear of
the pedestal.
With DC power, set the circuit breaker in the rear of the pedestal and
then set the module power supply to ON (up) for the module that was
added.
10 Reinstall the system monitor in the pedestal:
a.
Reconnect the RJ11 cable to J6, then the cable to J3. Reinstall the
system monitor.
b.
If the column houses the master system monitor, load LD 37, and
software re-enable the associated SDI port:
LD 37
ENL TTY x
****
11 Replace all module covers and the pedestal grill.
March 2013
enable the device associated with the port
exit LD 37
End of Procedure