Cabling Common Equipment in a Multi Group system
a.
At Clock 0: Connect the "J1 Clock" end of a Clock to FIJI cable
(NTRC46Ax) to the J1 end of the Clock to Clock cable.
b.
At Clock 1: Connect the "J1 Clock" end of a second Clock to FIJI
cable (NTRC46Ax) to the J2 end of the Clock to Clock cable.
3
Connect the Clock 0 to FIJI cable:
a.
Connect P1 of the NTRC46 cable from Clock 0 to J4 of the FIJI card
in Group 0, Shelf 0.
b.
Connect P2 of the NTRC46 cable from Clock 0 to J4 of the FIJI card
in Group 0, Shelf 1.
4
Connect a Clock 1 to FIJI cable:
a.
Connect P1 of the NTRC46 cable from Clock 1 to J3 of the FIJI card
in Group 0, Shelf 0.
b.
Connect P2 of the NTRC46 cable from Clock 1 to J3 of the FIJI card
in Group 0, Shelf 1.
March 2013
End of Procedure