Adding a module to the top of a column

NN43021-310
Standard 06.01
Adding a module to a column
In a DC-powered system, power to the column can remain on during this
procedure.
If conduit or other cabling runs through the top cap, you must tag and
disconnect the cables, pull them out of the way, and reroute them after the
new module and the top cap are positioned.
Procedure 65
Adding a module to the top of the column
1
Disconnect and remove the NT8D22 System Monitor for the column in the
rear of the pedestal (do not turn off the blower unit in the front of the
pedestals):
a.
If the column houses the master system monitor, load LD 37 and
software disable the associated SDI port:
LD 37
DIS TTY x
b.
Disconnect the RJ11 cable to J3, then the cable to J6, then pull the
system monitor out of the slot.
2
Turn off power as necessary:
With AC power, set the main circuit breaker for the column to OFF
(down) in the rear of the pedestal.
DANGER OF ELECTRIC SHOCK
Due to hazardous voltage in AC-powered systems,
power to the entire column must be shut down. This
shuts down all functions in the column.
With DC power, set the switch on the module power supply and the
circuit breaker in the rear of the pedestal to OFF (down) for the
module being added.
March 2013
disable the device associated with the port