Service Manual Cafitesse 100
A.3.3

Function: Boiler

The boiler (1) with a capacity of 6.5 l has
been designed as an open system (fig. 1):
The water inlet system prevents the boiler
from overflowing.
An overflow tube (2) prevents pressure
being generated in the container. (Fig. 1)
The water runs into the boiler via the non-
return valve in the boiler base (3). (Fig. 1)
The outlet spouts for the water coil (4) and
the hot water delivery tap (5) are situated
in the upper boiler part. (Fig. 1)
This guarantees the delivery of hot water,
as cold water is added in the boiler base
which then is heated up and afterwards
moves upwards.
Additionally, the outlet spouts positioned in
the upper boiler part guarantee that the
water level in the boiler does not fall below
these. Dry running of the heating element is
prevented.
A deflection plate (6) above the outlet spout
prevents lime particles from running through
the outlets.
An outlet (7) in the boiler base enables
drainage of the water. (Fig. 1)
5A - 22
Functions - Water System
3
Fig. 1
1
6
5
4
2
7
07.2004