Douwe Egberts Cafitesse 100 Service Manual page 125

Table of Contents

Advertisement

Service Manual Cafitesse 100
Remove the water outlet hose from the
boiler base.
Mount the shorter hose (1) included in the
kit 'tank top' to the boiler base outlet to
empty the boiler. (Fig. 4)
Mount the solenoid valve (2) (of kit 'tank
top') in the same way as the standard inlet
valve. (Fig. 4)
Mount the air duct.
Mount the housing cover.
CAUTION:
Make sure to connect the
ground connection to the
housing cover.
When the dispenser is equipped with a
heating plate in the housing cover,
replace the housing cover with heating
plate by the housing cover included in
the kit 'tank top'. Replace the heating
plate switch at the right front side of
the pot carrier (see corresponding
chapter) by the dummy cap (included
in kit 'tank top').
Mount the rear wall (included in kit 'tank
top'):
-
Insert the water outlet hose into the
round opening (3) at the bottom of the
rear wall. (Fig. 4)
-
Guide the plug connections S05/A (6) of
the main cable harness (former dry
running protection), S03/2 and S03/3 (7)
of the water tank switch cable harness
through the square opening (4) in the
middle of the rear wall. (Fig. 4)
-
Fasten the rear wall.
Connect the plug connection S05/A of the
main cable harness (former dry running
protection) to PIN 1 of the switch (5) (kit
'tank top'). (Fig. 4)
Connect the plug connections S03/2 to
PIN 2 and S03/3 ( 7 ) to PIN 3 of the switch.
(Fig. 4)
Mount the heating switch to the rear wall.
07.2004
Functions - Water System
7
6
4
5
3
Fig. 4
1
2
5A - 43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents