Service Manual Cafitesse 100
•
Push a clip onto the hose of the inlet valve
(do not fasten it).
•
Insert the pre-mounted hose coupling (1)
together with the cable harness into the
opening of the housing, and connect the
hose coupling (1) – inside the dispenser –
to the inlet tube (2) of the boiler. (Fig. 8)
•
Secure the inlet tube (2) and the hose
coupling (1) by means of the clip.
•
Insert 1-2 ribs of the corrugated hose (3)
into the opening of the housing. (Fig. 9)
•
Connect the cable harness of the pump
unit (4) to the rectifier. (Fig. 10)
ATTENTION: Observe the marks! (Fig. 10)
•
Connect the cable harness of the inlet
valve to the rectifier. (~)
5A - 48
Functions - Water System
3
Fig. 8
3
Fig. 9
4
+
~
Fig. 10
1
2
~
-