Key Switch - Douwe Egberts Cafitesse 100 Service Manual

Table of Contents

Advertisement

Service Manual Cafitesse 100
G.7.2 Key Switch
Preparation:
Switch off the dispenser and disconnect it
from the mains supply.
Disconnect the dispenser from the water
supply.
Installation:
Remove the operating panel cover (1) with
the screw (2). (Fig. 1)
Withdraw the front cover and the
advertising panel towards the side.
CAUTION:
When the front cover is mad e
of glass, there is the danger of
being inured due to incorrect
handling or breaking of the
glass.
Hold the operating panel at the cross-
shaped part (A) pull it towards the front
and remove it towards the top. (Fig. 1)
A
x x
x x
x
x x
x x
x
Fig. 1
07.2004
4
6
5
3
Remove the pc board (3) with 4 screws.
(Fig. 1)
Remove the stop button from the operating
panel with no imprints and mount it to the
operating panel with imprints.
Engage the lock (4) into the pc board base
and press the locking ring (5) downwards
until the stop. (Fig. 1)
Move the safety device for the lock (6) (2
parts) over the lock. (Fig. 1)
Mount the pc board to the new operating
panel with imprints.
Mount the new operating panel to the
dispenser.
Install the advertising panel and the front
cover.
Install the operating panel cover.
The clamping device included in the kit
is not required for mounting in this
case.
2
1
Functions - Housing
5G - 7