Service Manual Cafitesse 100
G.7.2 Key Switch
Preparation:
•
Switch off the dispenser and disconnect it
from the mains supply.
•
Disconnect the dispenser from the water
supply.
Installation:
•
Remove the operating panel cover (1) with
the screw (2). (Fig. 1)
•
Withdraw the front cover and the
advertising panel towards the side.
CAUTION:
When the front cover is mad e
of glass, there is the danger of
being inured due to incorrect
handling or breaking of the
glass.
•
Hold the operating panel at the cross-
shaped part (A) pull it towards the front
and remove it towards the top. (Fig. 1)
A
x x
x x
x
x x
x x
x
Fig. 1
07.2004
4
6
5
3
•
Remove the pc board (3) with 4 screws.
(Fig. 1)
•
Remove the stop button from the operating
panel with no imprints and mount it to the
operating panel with imprints.
•
Engage the lock (4) into the pc board base
and press the locking ring (5) downwards
until the stop. (Fig. 1)
•
Move the safety device for the lock (6) (2
parts) over the lock. (Fig. 1)
•
Mount the pc board to the new operating
panel with imprints.
•
Mount the new operating panel to the
dispenser.
•
Install the advertising panel and the front
cover.
•
Install the operating panel cover.
The clamping device included in the kit
is not required for mounting in this
case.
2
1
Functions - Housing