Douwe Egberts Cafitesse 100 Service Manual page 129

Table of Contents

Advertisement

Service Manual Cafitesse 100
As water can be left in the drain tube, hold
the container underneath the hot water
delivery cock (1). (Fig. 4)
Open the hot water delivery cock (1) and
drain the remaining water. (Fig. 4)
Make sure that the thermostat (2) was
turned to zero (counter-clockwise up to the
stop, heating off). (Fig. 5)
ATTENTION: If the thermostat is not turned to
zero, the dispenser starts
heating and actuates the
capillary tube limiter.
Loosen and remove the screws (3) of the
inlet valve (4). (Fig. 6, 7)
Push the inlet valve out of its seat and pull
it off.
Disconnect all contacts of the cable
harness (5) from the inlet valve. (Fig. 7)
Remove the clip from the tube.
Pull off the tube (6) from the inlet valve (4).
(Fig. 7)
07.2004
Functions - Water System
OFF
Fig. 4
2
Fig. 5
3
Fig. 6
4
Fig. 7
xxxxx
ON
STOP
xxxxx
1
5
6
5A - 47