K.2.2

Disassembly of the Control

Preparation:
Switch off the dispenser and disconnect it
from the mains supply.
Disconnect the dispenser from the water
supply.
Loosen the screw (2) and remove the
operating panel cover (1). (Fig. 1)
Withdraw the front cover and the
advertising panel (3) towards the side.
(Fig. 1)
CAUTION:
When the front cover is made
of glass, there is the danger of
being injured due to incorrect
handling or breaking of the
glass.
Remove the cooling compartment lid (4).
(Fig. 1)
Remove the rear wall (5). (Fig. 1)
Remove the housing cover (6). (Fig. 1)
Remove the air chute (7). (Fig. 1)
Disassembly:
CAUTION:
In order to prevent damaging of
the
pc
components due to electrostatic
charge, first touch a metal table
or a metal cupboard before
touching the pc boards.
Fig. 2
5K - 4
boards
and
their
8
Functions - Power Supply and Control
2
1
xx
xx
x
xx
xx
xx
xx
x
x
S T
O P
Fig. 1
Disconnect all plug connections from the
control (8). Hold the control at the bottom,
tilt it and remove it. (Fig. 2)
When the control is equipped with the
interface board I
2
C espresso/café cool (10)
loosen the mounting screws (9) and remove
the additional board. (Fig. 3)
Fig. 3
4
6
7
5
3
9
10
07.2004