Flow rate controller
•
The flow rate controller is installed on the
inlet side of the valve.
•
It reduces the flow rate of the incoming
water to approx. 5 l/min.
•
This ensures that the boiler overflow can
take the amount of incoming water if the
water inlet control fails.
•
The flow rate controller limits the flow rate
with a precision of +/-10 % independent on
the water supply pressure.
•
If the dynamic pressure falls below 0.8 bar
(11.6 psi) a sufficient flow rate cannot be
guaranteed.
•
In this case the water level in the boiler
cannot be controlled any more, especially
when the beverage delivery takes too long
or with frequent beverage deliveries.
•
Consequences:
•
Deviations in the dosing quantity
•
Possible blocking of the delivery (see
'error codes')
Filter sieve
•
A removable filter sieve (1) in the valve
inlet spout (in front of the flow rate
controller) prevents dust particles from
entering. (Fig. 1)
•
It is recommended to install an additional
filter sieve in the supply line when there are
regularly great amounts of dust particles in
the water supply lines. (Fig. 1)
07.2004
Functions - Water System