Service Manual Cafitesse 100
K.2
Disassemblies
K.2.1
Disassembly of the Power
Supply
Preparation:
•
Switch off the dispenser and disconnect it
from ther mains supply.
•
Disconnect the dispenser from the water
supply.
•
Loosen the screw (2) and remove the
operating panel cover (1). (Fig. 1)
•
Withdraw the front cover and the
advertising panel (3) towards the side.
(Fig. 1)
CAUTION:
When the front cover is made
of glass, there is the danger of
being injured due to incorrect
handling or breaking of the
glass.
•
Remove the cooling compartment lid (4).
(Fig. 1)
•
Remove the rear wall (5). (Fig. 1)
•
Remove the housing cover (6). (Fig. 1)
•
Remove the air chute (7). (Fig. 1)
Disassembly:
•
Withdraw the overflow hose (8) from the
overflow tray (9). (Fig. 2)
•
Lift the overflow tray towards the top off the
outlet elbow (10) and withdraw it from the
dispenser. (Fig. 2)
5K - 2
Functions - Power Supply and Control
2
1
xx
xx
x
xx
xx
xx
xx
x
x
S T
O P
Fig. 1
8
9
10
Fig. 2
4
6
7
5
3
07.2004