Service Manual Cafitesse 100
Counter display mode
or
Input
Display mode:
Display norm on:
The display is switched on during dispenser
operation.
Display indicates total amount of deliveries via
cup delivery button (110), or espresso delivery
button (120).
Display norm off:
The display is switched off, but the counter is
active.
Blocking of the beverage delivery at low
temperature
or
Input
The setting of "Temp. block:on" causes the block
of beverage deliveries as soon as the water
temperature in the boiler is < 80 °C (176 °F).
At the same temperature the yellow LED starts
flashing (long flash frequency).
If the water temperature in the boiler drops below
80°C (176°F) during a beverage delivery, the
dosing will be continued until the set delivery
volume is dispensed (delivery mode = portioned)
or until the push button is released (delivery mode
= continuous).
The default setting is 'Temp block: off', i.e. the
blocking of the beverage delivery at low
temperature is not activated.
07.2004
Display norm on
1=off 2=on
Temp block:##
1 = on 2 = off
Storing Values
or
Input
Press "1" to save all programmed values:
Disconnect the service device and switch
on the dispenser
-or-
Press "2" to cancel (previously programmed
data remain valid):
If the programming procedure is cancelled or
stopped, the dispenser will be ready for
operation 25 seconds after switching on,
while previously programmed data remain
valid.
Programming
Save values ?
1 = yes 2 = no
Values saved
SAT ready to use
Values not saved
SAT ready to use
4 - 17