Service Manual Cafitesse 100
Installation of the kit 'café cool'
Preparation:
•
Switch off the dispenser and disconnect it
from the mains supply.
•
Disconnect the dispenser from the water
supply.
•
Drain the water. (see chap A.2)
•
Remove the front part (1). (Fig. 2) (see chap.
G.2)
Installation:
•
Mount the valve support (6) to the cold water
inlet valve (5) (solenoid valve) as shown in
fig. 3.
•
Fasten the silicone hose (7) with hose
connector (3) and union nut (2) to the outlet
of the cold water valve. (Fig. 3)
•
Install the cold water valve at the left
dispenser wall with the outlet side mounted
towards the top. Use clamps (4) for this
purpose. (Fig. 3)
•
Push the hose towards the front between
boiler and side wall.
CAUTION:
The hose must not be bent or
squeezed.
•
Replace the outlet hose (8) at the boiler
outlet valve by means of the shorter outlet
hose (kit 'café cool'). (Fig. 4)
•
Insert the angular piece (2) into the housing
5A - 34
Functions - Water System
xx
xx
x
x x
xx
x x
xx
x
x
S T
O P
Fig. 2
7
2
3
4
6
5
Fig. 3
8
Fig. 4
1
07.2004