Service Manual Cafitesse 100
Installation of the kit 'café cool'
Preparation:
Switch off the dispenser and disconnect it
from the mains supply.
Disconnect the dispenser from the water
supply.
Drain the water. (see chap A.2)
Remove the front part (1). (Fig. 2) (see chap.
G.2)
Installation:
Mount the valve support (6) to the cold water
inlet valve (5) (solenoid valve) as shown in
fig. 3.
Fasten the silicone hose (7) with hose
connector (3) and union nut (2) to the outlet
of the cold water valve. (Fig. 3)
Install the cold water valve at the left
dispenser wall with the outlet side mounted
towards the top. Use clamps (4) for this
purpose. (Fig. 3)
Push the hose towards the front between
boiler and side wall.
CAUTION:
The hose must not be bent or
squeezed.
Replace the outlet hose (8) at the boiler
outlet valve by means of the shorter outlet
hose (kit 'café cool'). (Fig. 4)
Insert the angular piece (2) into the housing
5A - 34
Functions - Water System
xx
xx
x
x x
xx
x x
xx
x
x
S T
O P
Fig. 2
7
2
3
4
6
5
Fig. 3
8
Fig. 4
1
07.2004