Service Manual Cafitesse 100
A.2 Disassemblies
A.2.0
General Information
Drain water from the boiler
Switch off the dispenser and disconnect it
from the mains supply.
Disconnect the dispenser from the water
supply.
Loosen the screw (2) and remove the
operating panel cover (1). (Fig. 1)
Remove the front cover and the advertising
panel (3) towards the side. (Fig. 1)
CAUTION:
When the front cover is made
of glass, there is the danger of
being injured due to incorrect
handling or breaking of the
glass.
Remove the cooling compartment lid (4).
(Fig. 1)
Remove the housing cover (6). (Fig. 1)
Remove the air duct (7). (Fig. 1)
Remove the rear housing wall (5). (Fig. 1)
Place the dispenser in such a manner that
the rear housing wall is at the edge of the
table or counter.
Position a sufficiently large container
underneath it. (10 l bucket)
CAUTION:
There is the danger of being
scalded by hot water.
CAUTION:
Prevent the board from water.
Withdraw the drainage hose (8) of the boiler
and place it over the container. (Fig. 2)
Withdraw the plug (9). (Fig. 2)
Drain the water completely.
As there may still be water in the drainage
hose, place the container underneath the
hot water delivery tap.
Actuate the hot water delivery tap (10) and
drain the residual water. (Fig. 3)
5A - 2
Functions - Water System
2
1
xx
xx
x
xx
xx
xx
xx
x
x
S T
O P
Fig. 1
8
9
Fig. 2
OFF
ON
OFF
ON
POWER
Fig. 3
4
6
7
5
3
STOP
xxxxx
10
07.2004