Service Manual Cafitesse 100
A.2 Disassemblies
A.2.0
General Information
Drain water from the boiler
•
Switch off the dispenser and disconnect it
from the mains supply.
•
Disconnect the dispenser from the water
supply.
•
Loosen the screw (2) and remove the
operating panel cover (1). (Fig. 1)
•
Remove the front cover and the advertising
panel (3) towards the side. (Fig. 1)
CAUTION:
When the front cover is made
of glass, there is the danger of
being injured due to incorrect
handling or breaking of the
glass.
•
Remove the cooling compartment lid (4).
(Fig. 1)
•
Remove the housing cover (6). (Fig. 1)
•
Remove the air duct (7). (Fig. 1)
•
Remove the rear housing wall (5). (Fig. 1)
•
Place the dispenser in such a manner that
the rear housing wall is at the edge of the
table or counter.
•
Position a sufficiently large container
underneath it. (10 l bucket)
CAUTION:
There is the danger of being
scalded by hot water.
CAUTION:
Prevent the board from water.
•
Withdraw the drainage hose (8) of the boiler
and place it over the container. (Fig. 2)
•
Withdraw the plug (9). (Fig. 2)
•
Drain the water completely.
•
As there may still be water in the drainage
hose, place the container underneath the
hot water delivery tap.
•
Actuate the hot water delivery tap (10) and
drain the residual water. (Fig. 3)
5A - 2
Functions - Water System
2
1
xx
xx
x
xx
xx
xx
xx
x
x
S T
O P
Fig. 1
8
9
Fig. 2
OFF
ON
OFF
ON
POWER
Fig. 3
4
6
7
5
3
STOP
xxxxx
10
07.2004