Circuit - Water Coil

For the operation of the water coil, the
rectified secondary voltage of a transformer
is used.
When a delivery button is actuated, the
water coil is connected to the
microprocessor via a transistor.
The duration depends on the adjusted
volume.
The microprocessor monitors the circuit by
registering whether there is a voltage
applied at 'A'.
Standard/no delivery:
When no delivery button is actuated and
there is no voltage registered at 'A' by the
microprocessor for an interval of 5 sec., the
positive voltage is switched off and the
'empty' LED starts flashing.
F05
main
switch
T02
mains
Fig. 1
5A - 28
25 V~
V4070
'empty' LED
Functions - Water System
Standard/delivery:
When no delivery button is actuated, there
must be no voltage applied at 'A'.
If there is, however, a voltage applied at 'A'
in the case of an error, there will be no
error indication.
The error can only be noticed by the fact
that only concentrate will be delivered in
this case.
water coil
MP
delivery
button
+
transistor
'A'
transistor
07.2004