Douwe Egberts Cafitesse 100 Service Manual page 93

Table of Contents

Advertisement

Service Manual Cafitesse 100
Low temperature sensor
Disassembly:
Carry out the preparations for dismounting
the boiler cover. (see chap. 5A.2)
Disconnect the cable harness of the low
temperature sensor (1) from the control (2).
(Fig. 1)
Withdraw the low temperature sensor (3)
from the boiler cover (4). (Fig. 2)
Assembly:
Assembly is done in the reverse order.
When mounting the low temperature
sensor, ensure that the cable harness
(5) is placed between the guides (6) in
the boiler cover. Otherwise the float
switch function (7) may be affected.
4
3
Fig. 2
07.2004
Functions - Water System
2
1
Fig. 1
6
5
7
5A - 11