Douwe Egberts Cafitesse 100 Service Manual page 98

Table of Contents

Advertisement

Service Manual Cafitesse 100
Dry running protection
Carry out the preparations for dismounting the
boiler cover (1). (Fig. 1) (see chap. 5A.2)
Dismount the boiler cover. (see chap. 5A.2)
Unwind the sensor wire (2) from the
heating element (3). (Fig. 1)
Withdraw the dry running protection (4)
above the cover towards the top. (Fig. 1)
Assembly:
Assembly is done in the reverse order.
When mounting the dry running
protection, competely straighten the
sensor wire.
Guide the wire and the sealing disc
through the opening in the boiler cover.
Wind the sensor wire around the
heating element as follows:
-
Pull the sensor wire loosely up to
the recess in the heating coil which
is situated approx. 15 cm below the
heating element contacts.
Starting from the recess, the sensor
wire must be wound downwards
around the heating element. (Fig. 2)
-
Wind the sensor wire once around
one side of the heating element as
shown in fig. 2.
-
Wind the sensor wire 10 times
around both sides of the heating
element as shown in fig. 2.
-
Fasten the sensor wire to the
heating element by means of the
clamp. (Fig. 2)
5A - 16
Functions - Water System
2
3
Fig. 1
Fig. 2
4
1
07.2004