Service Manual Cafitesse 100
Installation:
Disconnect the plug connection S05/A (8)
from the main cable harness of the dry
running protection. (Fig. 3)
Remove the cable binder from the main
cable harness and pull the plug connection
S05/A to the rear of the dispenser.
Disconnect the plug connection S06/2 (9) of
the main cable harness from the thermos-
tat. (Fig. 3)
Connect the plug adapter (kit 'tank top') to
the free thermostat contact.
Connect the plug connections S06/2 of the
main cable harness and E01/B of the water
tank switch cable harness (kit 'tank top') to
the plug adapter.
Connect the plug connection S05/A of the
water tank switch cable harness (kit 'tank
top') to the free dry running protection
contact.
Remove the inlet valve. (see corresponding
chapter)
-
Place a cloth below in order to collect
water from the valve.
5A - 42
Functions - Water System
Fig. 3
8
9
07.2004