Service Manual Cafitesse 100
It must be observed that the bridges (1) on
the I
2
C espresso/café cool interface board are
closed. (Fig. 7)
Connect the I
2
C espresso/café cool interface
board (3) to the control (2) as shown in fig. 8.
Attach the control to the boiler.
Make sure that the two foils which are
situated behind the overflow safety thermostat
are placed in front of the control. (Fig. 9)
Connect the cable harness of the I
interface (1) to the plug ST10 (2) of the
control (blue) and to the plug ST01 (3) of the
interface board (blue). (Fig. 10)
When the dispenser is equipped with an older
EPROM version, replace the EPROM on the
control. Required: EPROM version "SAT1
V2.4" or more up to date.
Unplug the power supply. (see chap. 5K.2)
Remove the cup carrier.
Remove the coil of the inlet valve.
Remove the dummy cap at the right front
side of the pot carrier.
Insert the wirings of the cold water valve (4)
cable harness S30-NO and S30-C (5) into the
drip tray at the right front side. (Fig. 10)
Connect the wirings with the white rocker
switch and press the switch into the opening.
Connect the 6-pole bush BU02 (7) of the cold
water valve (4) cable harness to the plug
ST02 (blue) (6) on the interface board.
(Fig. 10)
Insert the control and connect the safety
thermostat.
Insert the plug ST09A (8) of the 24 V I
interface (10) cable harness into the 2-pole
bush BU09 on the control. (Fig. 10)
5A - 36
2
C
Fig. 7
Fig. 8
2
C
Fig. 9
Functions - Water System
1
2
3
07.2004