Service Manual Cafitesse 100
Close the boiler drainage hose by means of
the hose clamp and the plug (1). (Fig. 5)
Mount the tank support (included in kit 'tank
top') (2) to the rear wall as shown in fig.5.
(Fig. 5)
Place the tank (included in kit 'tank top') on
the housing cover as shown in fig. 5.
Connect the longer hose included in the kit
'tank top' as an outlet hose to the outlet
opening (3) of the tank and to the angular
piece (4) (included in kit 'tank top'). (Fig. 5)
Fasten the angular piece to the valve.
Switch on the dispenser with the main
switch.
CAUTION:
Make sure that the heating
switch (3) at the rear wall of
the dispenser is switched off,
otherwise the dry running
protection would be activated.
Fill the tank with water (drinking water
quality) until the water reaches the
maximum mark in the tank (approx. 10 l).
Close the tank.
Switch on the heating switch (5) and carry
out a functional test. (Fig. 5)
5A - 44