2.7

Reinstalling the scanner wire

A. Procedure
1. Move the V-mirror unit [1] to the paper exit side,
and pass the optical positioning jig [2] through
the V-mirror unit [1] from the front side.
Note:
• Be careful not to damage the mirror with the
jig.
• When reinstalling the scanner wire, be sure to
fasten the V-mirror with the optical position-
ing jig.
2. Drop into the fitting hole of the drive pulley [4] a
metal bead [3] provided at the center of each of
the scanner wires /F [1] and /R [2], and starting
from this hole, wind the scanner wire 2.5 turns
[5] outwards and 3.5 turns [6] inwards.
Note:
• For the scanner wires /F and /R, common
wires are used.
• Be sure to wind each of scanner wires so that
the wire terminal is on the outside and the
metal bead [7] on the inside.
• Be sure to wind each of scanner wires so that
both ends of the wire come out under the
drive pulley.
• Be sure to wind each of the scanner wires
closely around the drive pully with no wire
running on another wire.
3. After winding the scanner wires /F and R/, be
sure to fasten each wire end with a tape [8] so
that it will not come off.