FIXING
4. Remove 2 screws [1] and open the fixing upper
unit [2].
Note:
• The screw [1] is a shoulder screw. When
attaching it, be sure to set the shoulder sec-
tion securely into the screw hole.
5. Remove 2 faston terminals [1] at the front, and a
clamp fixing screw [2], 2 faston terminals [3] and
a screw [4] at the rear. And then remove the fix-
ing plate [5] and pull out gently the fixing heater
lamps /1 and /2 [6] from the fixing roller /U [7] for
removal.
Note:
• When removing the faston terminal, be sure to
hold it at the connector.
6. Reinstall the above parts following the removal
steps in reverse.
Note:
• Be sure to reinstall the fixing heater lamp so
that the maker mark indication comes to the
rear.
• When reinstalling the fixing heater lamps,
please note that the lamp fitting holes on the
fixing plate are different.
CF5001 Field Service Ver.1.0 Sep 2003
[1]
[2]
[3]
[5]
1-78
[2]
[1]
8050ma3101
[1]
[7]
[6]
[4]
8050ma3102