CF5001 Field Service Ver.1.0 Sep 2003
8. Fold the outputted paper in the paper feed
direction and check the amount of error of the
lines on both sides.
• Standard value: Within ± 2mm
9. When the value is not within the standard,
press the C button while pressing the P button.
10. Enter a numeric value through the numeric
keys and press the [SET] key.
• Setting range: -40 to +40, 1 step = 0.1mm
11. Repeat steps 6 to 10 until the standard value
can be obtained.
12. Press the [PREVIOUS SCREEN] key to return
to the "Centring adjustment mode menu
screen."
(2) Scanner centring adjustment
Adjust the centring when scanning the platen origi-
nal.
This adjustment changes the reading timing of the
CCD.
This adjustment can be shown in the key operator
mode by setting the DIPSW12-1 to 1.
Note:
• Make sure that the printer centering adjust-
ment has been completed.
a.
Procedure
1. Enter the 36 mode.
2. "36 mode menu screen"
Press the [2. Image adjustment] key.
3. "Image adjustment mode menu screen"
Press the [4. Centring adjustment] key.
4. "Centring adjustment mode menu screen"
Press the [2. Scanner centring adjustment]
key.
5. "Scanner (platen) centring adjustment screen"
Press the [COPY SCREEN] key.
6. Select the A3 or 11 x 17 paper and press the
START button with a test chart set to the origi-
nal glass.
7. Fold the outputted paper in the paper feed
direction and check the amount of error of the
lines on both sides.
• Standard value: Within ± 2mm
8. When the value is not within the standard,
press the C button while pressing the P button.
9. Enter a numeric value through the numeric
keys and press the [SET] key.
• Setting range: -30 to +30, 1 step = 0.1mm
10. Repeat steps 6 to 9 until the standard value is
obtained.
11. Press the [PREVIOUS SCREEN] key to return
to the "Centring adjustment mode menu
screen."
2-77
36 MODE