CF5001 Field Service Ver.1.0 Sep 2003
III SERVICE TOOL
1. ISW
1.1
Description of the ISW
ISW (In-system Writer) is an operation to rewrite the
control program stored in the flash ROM on a vari-
ety of control boards in Minolta's digital copier with-
out removing the boards from the main body of the
copier. ISW allows you to update the version of the
control program without replacing the board or to
install the latest program when replacing the board.
[ISWTrns (PC software)] is provided to execute ISW,
which rewrite the program by connecting a PC to
the digital copier. The software rewrites the control
program stored in the flash ROM in the copier main
body directly.
1.2
Installing the USB driver for
ISWTrns
Note:
• It is required to install the USB driver for
ISWTrns to perform ISW via USB on this
machine. See the installation procedure file
attached to ISWTrns for the installation proce-
dure.
• Before performing ISW via USB, be sure to
turn on the USB radio button in [Setting (S)] -
[Set Communication (C)] in ISWTrns and
press the OK button.
• Only ISWTrns is supported for ISW in this
machine.
3-1
ISW