Parallel Port Setup - Konica Minolta CF5001 Service Manual

Konica minolta cf5001 laser mfp service manual
Hide thumbs Also See for CF5001:
Table of Contents

Advertisement

CF5001 Field Service Ver.1.0 Sep 2003
File Check button
9
Click this button when send files are listed in
the Send File Info list in
sum of the transfer files displayed (file check-
sum) is calculated and attached to each file.
Further, the calculated checksum is compared
with the checksum storage file (*.SUM)
attached to the transfer file (write data) to dis-
play the result of the comparison in the follow-
ing format:
[OK] = Matched
[NG] = Unmatched
[??] = Checksum file (*.SUM) not found
File Send Button
10
Perform transmission of transfer files
2.1.4
8
, and a file check-
3-13
UPDATING WITH ISW Trns

Parallel port setup

If a parallel data transfer is to be executed with
the ISW Trns program, the ECP mode setting
of the PC parallel port should be cleared. ISW
Trns does not support parallel data transfers. If
a parallel data transfer is launched with the PC
set in ECP mode, the transfer could be aborted
by an error occurring in between. It would be
necessary, therefore, to disable ECP mode
before run ISW Trns on a PC with the ECP set-
ting.
Instructions on how to disable ECP mode are
given below.
Step
Procedure
1
Boot the PC.
2
Open the System icon in the Control Panel
and click the Device Manager tab. Then,
search for LPT1 in Ports (COM/LPT1).
Note:
• If LPT1 appears as "ECP Printer Port
(LPT1)," then it is an ECP port.
• If LPT1 appears as "Printer
(LPT1)," then it is a regular parallel port.
3
With an ECP printer port, change the
BIOS setting of the PC to disable the ECP
port.
Note:
• Because the BIOS setting depends on
the PC, check with your system admin-
istrator on how to disable ECP mode.
4
When the BIOS change is complete, open
the System icon in the Control panel and
change the parallel port driver.
5
Run a send test to verify the successful
operation.
Note:
• If a transfer succeeds on one copier
model, then transfers would be suc-
cessful on all models.
Port