Konica Minolta CF5001 Service Manual page 183

Konica minolta cf5001 laser mfp service manual
Hide thumbs Also See for CF5001:
Table of Contents

Advertisement

C-208 Ver.1.0 Sep 2003
C. Reinstalling the wire
1. Insert the up/down wire /A [2] into the hole [1]
provided on the upper surface of the LCT main
body.
2. Reinstall the up/down wire /A [2] onto the guide
pulleys [3], [4] and [5] in this order.
Note:
• When reinstalling the up/down wire /A [2] onto
the guide pulleys [3], [4] and [5], be sure to
insert the wire into the pulley through the
notch [6] provided on the side of each pulley
and then move the wire cover [7] of each pul-
ley to the wire that has been already inserted.
When moving the wire cover [7], move it first
to the position where the notch [6] can be
avoided and then move the wire in the notch
[6] into each pulley.
3. Insert the up/down wire /A [2] into the wire
installation hole [9] provided inside the up/down
drive shaft [8].
Note:
• The up/down drive shaft [8] is provided with 3
wire installation holes each on the front side
and the rear side. In this step, the inner-most
wire installation hole is used.
4. Insert the drive pulley [10] into the up/down
drive shaft [8] so that the notch [11] of the drive
pulley [10] comes to the position in which the up/
down wire /A [2] is put.
5. Fit the E-ring [12] and fasten the drive pulley
[10].
[6]
[7]
[2]
[4]
[2]
[5]
[7]
[2]
[6]
1-153
TRAY UP/DOWN
[2]
[1]
[3]
[8]
[10]
[11]
[10]
[2]
[12]
[9]
[8]
lt2113039

Advertisement

Table of Contents
loading

Table of Contents