FIXING
4. With a thermostat positioning jig (4969-1885-01)
set between the thermostat /1 [1] and the fixing
upper roller [2], fasten the thermostat mounting
board with 2 screws so that the mounting board
becomes the same thickness as the positioning
jig.
• Specification: a = 3.1 ± 0.2mm
5. Apply 2 screws [1] of the thermostat section with
screw lock paint.
CF5001 Field Service Ver.1.0 Sep 2003
a
1-90
[1]
[2]
8050ma3120
[1]
8050ma3121