4. With a new sponge roller and the shaft put
together at their respective concave sections [1],
install the sponge roller securely to the shaft by
pressing it down until a click sound is heard.
5. Reinstall the above parts following the removal
steps in reverse.
Note:
• When reinstalling, be sure to insert the pin at
the rear of the intermediate conveyance roller
securely into the receiving groove.
2.3
Removing and reinstalling of
the paper exit opening unit
A. Procedure
1. Remove the following parts:
• Top cover /1, or an optional PI-installed machine
(PI)
• Top cover /2
• Side cover
• Rear cover
• Main tray
• Main paper exit opening cover
2. Remove a screw [3] of the paper exit open/close
link [2] of the paper exit opening unit [1].
[1]
[1]
1-168
FN-9/FN120 Ver.1.0 Sep 2003
[1]
fs2153016
[2]
[3]
fs2153017