Konica Minolta CF5001 Service Manual page 113

Konica minolta cf5001 laser mfp service manual
Hide thumbs Also See for CF5001:
Table of Contents

Advertisement

CF5001 Field Service Ver.1.0 Sep 2003
4. Remove the fixing upper lamps /1 and /2.
5. Remove the rear side O-ring [3].
Remove the heat insulating sleeve /U [4] and the
ball bearing [5] at the rear side, from the fixing
roller /U [6].
Note:
• Be careful not to damage the surface of the
fixing roller.
6. Remove the fixing roller /U [6].
7. Remove the O-ring [1] and then remove the fix-
ing gear [2].
8. After removing the O-ring [3] of front side,
remove the heat insulating sleeve /U [4] and the
ball bearings /U [5] from the fixing roller /U [6].
9. Reinstall the above parts following the removal
steps in reverse.
Note:
• After replacing the fixing roller, check whether
the fixing temperature sensor /3 is contacting
with the roller.
• When fixing temperature sensor /3 is soiled
with paper dust, clean the sensor with drum
cleaner and cleaning pad.
• When having replaced the fixing roller /U, be
sure to make adjustments by referring to the
36 mode "Adjustment item list." Otherwise,
poor images may result.
• Be sure to apply the inner and outer peripher-
ies of the heat insulating sleeve with Maltemp
FF-RM (or, Solvest 240) before reinstalling it.
• When reinstalling them, be sure to take note
of the directions of the ball bearing and the
flange of the heat insulating sleeve. Reinstall
them so that their upper surface turns to the
inside as seen in the picture in which they are
arranged after disassembly.
[3]
[4]
[5]
[6]
1-83
FIXING
[5] [4] [3] [2]
[1]
[5] [4]
[3] [2] [1]
[5]
[4]
[3]
8050ma3108