Static RP Configuration
Use the Static RP Configuration page to display or remove the configured
RP . The page also allows adding new static RPs by clicking the Add button.
Only one RP address can be used at a time within a PIM domain. If the PIM
domain uses the BSR to dynamically learn the RP, configuring a static RP is
not required. However, you can configure the static RP to override any
dynamically learned RP from the BSR.
To access the page, click IPv4 Multicast → PIM → Static RP Configuration
or IPv6 Multicast → PIM → Static RP Configuration.
Figure 43-35. Static RP Configuration
Adding a Static RP
To add a static RP for the PIM router.
1 Open the Static RP Configuration page.
2 Click Add.
The Add Static RP page displays.
Managing IPv4 and IPv6 Multicast
1203
Need help?
Do you have a question about the PowerConnect 8024 and is the answer not in the manual?