Indicator
GEL
A
(Global Error
LED)
CSS
B
(Customer
Self Service)
C Identification
D Memory
E System fans
F
PCI card
G AUX power
H iRMC
TX1330 M1
Status
Description
off
no critical event (non CSS component)
orange on
prefailure detected (non CSS component)
non CSS component failure
Possible reasons:
orange
– sensors report overheating
flashing
– sensor is defective
– CPU error
– software reports an error
off
no critical event (CSS component)
yellow on
prefailure detected (CSS component)
yellow
CSS component failure
flashing
blue on
Localizes the server
blue
Local monitor off
flashing
off
memory module operational
orange on
memory module failure
off
fan running
orange on
fan failure
off
PCI card operational
orange on
PCI card failure
yellow on
AUX voltages are within range
green
iRMC S4 management controller is
flashing
operational
Upgrade and Maintenance Manual
Appendix
325
Need help?
Do you have a question about the Server PRIMERGY TX1330 M1 and is the answer not in the manual?