11 Physical Interfaces
128
Field
Call Number
The menu Advanced Settings consists of the following fields:
Fields in the Advanced Settings menu.
Field
X.31 (X.25 in D Chan-
nel)
X.31 TEI Value
X.31 TEI Service
Description
kbps)
This parameter is exclusively used by Media Gateway.
Only for Port Usage
figuration Type
Only for the devices RTxxx2
Enter the basic number of the Point-to-Point.
With incoming calls, this basis call number is cut off by the
called party number
With outgoing calls, this main number is attached to the number
to be called (calling party number).
Description
Select whether you want to use X.31 (X.25 in the D channel)
e.g. for CAPI applications.
The function is enabled with
The function is disabled by default.
Only if X.31 (X.25 in D Channel) is enabled
With the ISDN autoconfiguration, the X.31-TEI is detected auto-
matically. If the autoconfiguration has not detected TEI, you can
manually enter the value assigned by the exchange.
Possible values are
to
The default value is
(for automatic detection).
Only for X.31 (X.25 in D Channel) enabled
Select the service for which you want to use X.31 TEI.
Possible values:
: Leased line over B channel 2 (64
and ISDN Con-
.
.
bintec Rxxx2/RTxxx2