15 MARCH 1987
- PAPER SIZE SENSOR REPLACEMENT -
1. Remove the paper size sensor [A] from the sensor bracket [B] (1
screw and 1 connector).
Position the projection of the sensor in the hole
2. Install a new sensor.
of the sensor bracket.
NOTE: Do not overtighten the screw when securing the new sensor.