Ricoh FT4480 Field Service Manual page 11

Table of Contents

Advertisement

15 MARCH 1987
5.
Remove the
6.
Remove the
7.
Remove the
NOTE: Save the scanner lock plate for future use.
8.
Reinstall the left cover and rear cover.
9.
Pull out the fusing unit [D] to the lock position and remove the fusing
unit cover [E] (2 screws).
10.
Prime the oil supply pad [F] with silicone oil.
11.
Fill the oil tank [G] with silicone oil.
Manually operate the oil pump lever [H] and confirm the proper
12.
operation and condition of the silicone oil supply system.
13.
Reassemble the fusing unit and return it to its original position.
rear cover [A] (2 screws).
left cover [B] (4 screws).
scanner lock plate [C] (1 screw).
1-6

Advertisement

Table of Contents
loading

Table of Contents