8. CORONA
- CORONA WIRE REPLACEMENT -
CAUTION: -
Do not handle new corona wires with your bare hands. Oil on the wire
will cause uneven charge on the drum.
-
Do not rub the corona wires with rough material (sandpaper, etc.)
because the corona wires are carbon-coated.
When removing the endblock covers, be careful not to break off the side
hooks.
-
Do not use any solvent to clean the wire as it will cause uneven charge
on the drum.
I. CHARGE CORONA WIRE
1. Slide the wire cleaner [A] away from the front endblock [B] as shown.
2. Remove the front [C] and rear [D] end block covers.
3. Slide the wire cleaner back to the front end and remove it.
3-67