15 MARCH 1987
7. TRANSPORT
- TRANSPORT UNIT AND TRANSPORT BELT REMOVAL -
1.
Swing the toner collection bottle cover [A] to the left (1 screw).
2.
Disconnect the toner overflow sensor connector [B].
3.
Remove the toner collection bottle [C].
4.
Remove the development unit [D], PTL board [E], and the charge
corona unit [F] (1 screw).
5.
Lower the T/S corona unit [G].
6.
Remove the drum stay [H] (1 knob [I] and 1 screw), the cleaning unit
and the drum.
NOTE: Be sure the protective sleeve is installed before removing the drum.
7.
Remove the fusing unit.