Ricoh FT4480 Field Service Manual page 135

Table of Contents

Advertisement

15 MARCH 1987
- Method B: Using a Digital Multimeter -
Perform steps 1 and 2 of method A.
1.
Confirm that the main switch is off and turn on DIP SW No. 1-1 on
the operation panel.
2.
Open the manual feed table and remove the magnetic catch bracket
(1 screws).
Remove the rear cover (2 screws).
3.
4.
Hook up the multimeter leads as follows:
Note: Hook up the positive lead using a crocodile clip as shown.
Positive lead to pin 1 of CN212 on the main board
Negative lead to TP 201 (GND) and select the 20-volt range on the
multimeter.
5.
Close the manual feed table.
3-84

Advertisement

Table of Contents
loading