15 MARCH 1987
Mode No.
28 Auto Sort Mode
29 Fusing Unit
Idle
35 Toner Supply
49 Fusing Tempera-
ture Change
52 Fusing Temper-
ature
55 VSG, VSP
Voltage
56 ADS lnput Refer-
rence Voltage
59 Bias Voltage
60 Toner Supply
Recovery
Function
Selects Sort Mode
automatically in ADF
mode.
Selects fusing unit
idling mode
Changes toner supply
interval.
a) ID sensor checks
every 5 copies.
b) Toner end level
changes to 0.65V.
Changes fusing temp.
Displays the fusing
temperature.
Displays VSG, VSP
voltage
Displays ADS voltage
Displays bias voltage
Recover toner volume
if the Vsp is above
0.5V.
a) Press Start key.
b) Toner supply clutch
turns on.
c) Free run starts.
d) Vsp becomes less
than 0.5V.
e) Free run stops.
2-10
Data
Factory
Setting
0: Manual
0
1: Auto
0: No idling
0
1: idling
0: Standard
0
1: Increase
0: Standard
0
1: Low
2: Higher
3: Highest
-
-
-
Remarks
Sorter and DF must
be installed.
Copier will idle
for 10 seconds.
Refer to the NOTE 3.
Standard:
Every 10 copies,
0.75V.
178 - 184°
174 - 180°
182 - 188°
186 - 192°
Press the enter
key twice to
Display Vsp.
For use with SP
Mode "9".
Refer to the ADS
adjustment proce-
dure.
Press the Start key
to indicate the vol-
tage.
Use this mode if
the image density
is low. (Black toner
only).
Refer to the NOTE 2
for color toner

Advertisement